Torch – 1 Piece – Organics – Wear Metals – 550-22W

$445

Teledyne / Leeman Labs Profile Radial Series

Description

Torch – 1 Piece – Organics – Wear Metals – 550-22W

Part Number:
PG550-22W

Cross Reference(s)
None Available

Instrument Compatibility:
Teledyne / Leeman Labs Profile Radial Series

Detail:
Quartz, 1 Piece, 1.0mm ID Injector, 12/5 Ball Joint, Organics, Wear Metals.

What is the Role of the ICP Torch?

A plasma is an ionized gas, consisting of positively charged ions and free (unbound) electrons. The role of the plasma (ICP) in ICP-MS is to ionize the sample. In contrast to so-called ‘soft’ ionization sources in other forms of mass spectrometry, the ICP is a ‘hard’ ionization technique because it completely atomizes most molecules in the sample.

ICP-MS instruments use an argon plasma, although helium plasma is also an option. Although there are several advantages to using helium, argon is the gas of choice since the cost of helium is prohibitive.

How the ICP Torch Ionizes a Sample.

The RF generator supplies power to the load coil, creating a high-frequency alternating current. This, in turn, induces a time-varying electromagnetic field in the torch. As a result, with argon gas flowing through the torch, the application of a high-voltage discharge (called a Tesla spark) ionizes a fraction of the argon atoms generating ions and electrons.

The electromagnetic field in the torch then acts on the ions and electrons. As a result, they accelerate and collide with other argon atoms. If these collisions impart enough energy, additional atoms ionize creating electrons and ions that propagate the cascade.

As a result, the movement of electrons and ions in the torch generates tremendous heat. The result is an ICP, which reaches a temperature of up to 10,000 Kelvin (hotter than the surface of the sun).

What Is PFA Inert?

PFA is frequently employed as an inert substance in sample equipment on geochemical or environmental analytical chemistry field sites to assist in avoiding trace amounts of metallic ion contamination.

Features of Torch – 1 Piece – Organics – Wear Metals

Single Piece Torch

Single-piece inductively coupled plasma (ICP) torches have narrow bore injectors (1.0 mm or 1.5 mm) designed to improve plasma stability and reduce plasma loading when used with organic solvents. They are the least expensive type of torch to buy initially, but they are also the least versatile and must be replaced entirely if any component is damaged. Single-piece torches can also be expensive consumables that require regular maintenance and replacement, especially when used with aggressive sample matrices like hydrofluoric acid, organic solvents, and high total dissolved solids.

Organics

In an ICP torch, organics refers to non-water-soluble organic solvents. ICP-OES instruments can analyze organic solvents directly, without dilution, at room temperature. As a result, this simplifies the analysis of petrochemical samples, since many dissolve in solvents like kerosene, xylene, methanol, or ethanol.

Do you have questions? Contact Precision Glassblowing to Learn More.

Do you have questions? Visit our FAQs or Technical Information. And, there are several ways to contact Precision Glassblowing. Click here to pick one that works for you.

 

Additional information

Material

Quartz

Type

One-piece fixed with 12/5 Ball

Applications

Specifically for organic samples such as oils or fuels

Injector

Tapered, 1..0mm ID.

Alignment Pin(s)

None

Fittings

Not Included